Chapter 3 AMI BIOS Setup 3-20
Options summary :
SYS/CPU Smart
Fan Control
Auto by RPM
Auto by Duty-Cycle Default
Manual by RPM
Manual by
Duty-Cycle
Select CPU Smart FAN mode
Auto by RPM: Automatically controlling the fan to maintain target
Fan Speed.
Auto by Duty-Cycle: Automatically controlling the fan to maintain
target temperature.
Manual by RPM: Manually controlling the fan with a given Fan
Speed.
Manual by Duty-Cycle: Manually controlling the fan with a given
control PWM.
Target Temp.
Sensor
CPU Temperature Default
Chassis Temperature
PCH Temperature
Select target temperature source.