3-5
Chapter 3: BIOS setup
3.3.3 Hardware Monitor
FAN2Conguration
Thesub-itemsinthismenucongureavailablefansonthesystem.
SYS Smart Fan control [Auto by Duty-Cycle]
SelectSmartFancontrolmode.Congurationoptions:[AutobyRPM][Autoby
Duty-Cycle] [Manual by RPM] [Manual by Duty-Cycle]
Target Temp. Sensor
Congurationoptions:[CPUTemperature][SYSTemperature]
Temperature Bound 1~4
Input temperature setting. Input value range: [0~127]
Segment 1~5 Speed (PWM)
Input fan speed in PWM duty-cycle. Input value range: [0~100]
The following item replaces Segment 1~5 Speed (PWM) when SYS Smart Fan
Control is set to Auto by RPM.
Segment 1~5 Speed (%)
Input fan speed percentage. Input value range: [0~100]
Full Speed Count [3000]
Input fan full speed count value. Input value range: [500~15000]
Full Speed Count is only available when SYS Smart Fan Control is set to
Auto by RPM.
Manual Setting [3000]
SpecifyxedRPM.Inputvaluerange:[500~15000]
Manual Setting is the only item available when SYS Smart Fan Contorl is set
to Manual by RPM.
Manual Setting [100]
SpecifyxedDuty-Cycle.Inputvaluerange:[0~100]
Manual Setting is the only item available when SYS Smart Fan Contorl is set
to Manual by Duty-Cycle.